Configurations:
Technical Specification:
| Item | Description |
| ECG 12 Channel with | 12 Lead Electrode |
| ECG Weight | 5 Kg |
| Resolution | 5uV/LSB |
| Sampling Rate for pace maker | 32,000 samples/second/channel |
| ADC | 24 bits |
| Interpretation | Glasgow algorithm |
| Pacer Detection Sampling Rate | 32,000 Sample/Second/Channel |
| Display Size | 10.1″ high-resolution color LCD, operate by full-touch screen |
| Display Resolution | 800×1280 pixels |
| Battery Type | 5200mAh |
| Battery capacity | 400 ECGs |
| Internal memory | 4000 ECGs |
| Preview full ECG report on screen | Yes |
| Preview and review full ECG report on screen | Yes |
| Connect to external printer | Yes |
| Barcode reader | Yes |
| USB flash drive storage of PDF and XML outputs | Yes |
| Type | Gun-type |
| Screen | Capacitive touch screen |
| Tube pressure | 60.0,650,700KV (adjustable in three levels) |
| Tube current | 2.5.3.5Ma (adjustable in two levels) |
| Focus size | 0.4mm |
| Focus-skin distance | 200.0mm |
| Exposure time | 0.01-1.05 |
| KV Ripple Frequence | <1.0% |
| Inverting Frequency | > 100.0KHZ |
| Special function | Operation with Remote controller |
| Lithium battery capacity | DC22.2V/950.0mAh |
| Radiation dose | 2:447mGy |
| Surface leakage radiation dose | 0:0007mSv |
| Net Weight | 2.0KG |
| Gross Weight | 4.0KG |
| Packaging Size | 34.0cm X 34.0cm X 15.0cm |
POWERFUL PLATFORM
Our HM-03US Series ultrasound systems leverage harold’s advanced technology and the innovative “E-Res” platform. This patented technology enhances diagnostic accuracy and confidence. E-Res’s adaptive imaging and analysis streamline examinations, ushering in a new era of workflow efficiency and Al technology

ADVANCED IMAGING TECHNOLOGY AND FUNCTIONS
DEDICATED TECHNOLOGIES FOR OBS
AND GYN APPLICATION
ADVANCED CARDIOLOGY
TECHNOLOGY
]]>
| Leads | 9/12 leads simultaneous acquisition |
| Sampling Rate | 16000 Hz/channel/second |
| AID Resolution | 24 bits |
| HR Range | 30 ~ 300 bpm |
| Time Constant | ≥3.2 s |
| Polarizing Voltage | ± 600 mV |
| Input Impedance | ≥50 MO (10 Hz) |
| Frequency Response | 0.01 ~ 300 Hz |
| Noise Level | ≤12.5 µV (p -p) |
| DFT Filter | 0.01/0.05/0.32/0.67 Hz |
| EMG Filter/Low Pass | 25/35/45/75/100/150/270/300 Hz |
| Pacemaker Detection | Amplitude: ±750 uV ~ ± 700mV, Width 50 us~ 2.0 ms Sampling Frequency: 16000 Hz |
| LCD Display | 10.1 inch TFT color LCD (1024*600) with touch screen |
| Power Supply | AC input with external power adaptor of 100 ~ 240 V, 50/60 Hz Rechargeable Lithium battery (4400 mAh) supporting 400 exams |
| Recording Speed | 5/6.25/10/12.5/25/50 mm/s |
| Recording Paper | Z-fold 210x295 mm x 100 sheets, Roller type 210 mm x 20/30 m |
| CMRR | ≥120 dB |




Clear
Informative
Professional
Simple

Simuluneous 9/12 Lead acquishion Real time waveform freezing

Appllulble to recordlng paper of z-fold/roll type
Multlple print out format of 3/4/6/7/9/12 channel

Portable deslgn

Sepante ECG recorder
Accurate pacemake detection
]]>
4 USB ports for data transmitting and connection
with printer, keyboard, mouse, barcode scanner etc.

No barrier around the needle Suitable
for either left hand or right hand

4 reagents totally, 3 are routine use.
2 years shelf life
All key components are imported, high quality and longer life. Syringe maintenance free.

Real double optical channel test, both for Diff and BASO.
BASO channel with optical counting, more precise.

Technical Specification
| Principles | Flow Cytometry (FCM) + Tri-angle laser scatter+ |
| Chemical staining method for WBC differention | |
| Impedance method for RBC and PLT test | |
| Cyanide free colorimetry for HGB test |
| Parameters | 23 reportable parameters: |
| WBC, Neu#, Lym#, Mon#, Eos#, Bas#, Neu%, Lym%, | |
| Mon%, Eos%, Bas%, RBC, HGB, HCT, MCV, MCH, | |
| MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT | |
| 4 research parameters: ALY#,ALY%,LIC#,LIC% | |
| 3 histograms for WBC, RBC and PLT | |
| Four 2D scattergrams for WBC differention |
| Sample Volume | 20µL |
| Linearity Range | WBC: 0.00-300.00x 109/L |
| RBC: 0.00-8.50×1012/L | |
| HGB: 0-250g/L | |
| PLT: 0-3000x 109/L | |
| HCT: 0.0-67.0% |
| Repeatability | WBC≤2%( 4.0-15.0×109/L) |
| RBC≤l .5%(3.5-6.0x 1012/L) | |
| HGB≤l .5%(70-120g/L) | |
| MCV≤l%(70-120fL) | |
| PLT≤6.0%(100-149x 109/L) | |
| ≤4.0%( 150-500x 109/L) |
| Throughput | Up to 60 tests per hour |
| Display | 10.4 inches high resolution TFT touch screen |
| Printout | External printer,compatible with multiply laser/
inkjet printers, compatible with various formats and user-defined formats |
| Storage | Up to 50,000 records |
| Sample mode | Whole blood, capillary whole
blood and pre-diluted modes |
| Interface | 4 USB ports, 1 LAN port |
| Power requirement | 100V-240V∼, 50/60Hz, ≤200VA |
| Dimension | 364mm(W)*498mm(D)*431mm(H) |
| Net weight | 28kg |
| Machine type: | Random access, open reagent & locked reagent (optional) |
| Test speed: | Constant 200 tests/hour (Mono reagent or double reagent) |
| Test principle: | Colorimetric method, turbidimetry |
| Test method: | 1 point end, 2-point end, Fixed-Time, Kinetics |
| Calibration type: | Linear & nonlinear |
Multifunctional precision sampling probe
Excellent mixer design
High precision ceramic syringe
Reagent tray & Sample tray
Reaction tray
Advanced operating system
Technical specifications
Sample unit
| Sample tray: | 40 sample positions |
| Sample tube: | Micro cup & test tube & blood collection tube can be used.
(12-13) mm X (25-100) mm |
| Sample volume: | 2-30μL, step by 0.1μL |
| Sample probe: | Liquid surface detection, timely tracking for liquid volume.
Collision avoidance |
| Sample barcode : | Sample barcode reader (optional) |
Reagent unit
| Reagent tray: | 80 reagent positions (40 for R1 & 40 for R2), Non-stop
cooling system with Peltier pad inside, 24 hours 2°C-14°C, open system, could accept any reagent. |
| Reagent volume : | 20-300μl, step by 1μl |
| Reagent needle: | Liquid surface detection, timely tracking for liquid volume.
Collision avoidance. |
| Regent barcode: | Regent barcode reader (optional) |
Reaction unit
| Reaction tray: | 44 reaction cuvettes, new amorphous optical plastics
reaction cups, perfect transmittance. |
| Reaction volume: | 150μl-330μl |
| Reaction time: | 10 minutes |
| Temperature: | Peltier pad incubation system, reaction temperature
(37°C ± 0.1 °C) |
Mixing system
| Mixer: | Paddle-type mixing, effective reducing of carry-over |
Optical system
| Light source: | Halogen lamp |
| Wavelength: | 340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm;
700nm (4 more options) |
| Absorbance range: | 0-4.0 Abs |
| Resolution: | 0.0001 Abs |
Operating system
| Operation system: | Windows XP, Windows 7, Windows 8, Windows 10 |
| Data processing: | Automatic calibration, test combination, effective time
management of reagents, serum index, whole process detection, linear expansion of enzyme, blank deduction, dirty cuvette memory, cross infection prevention, patient information memory and association input, automatic report audit, data fuzzy query, report statistics and printing, reference range grading, alarm information classification, user operation privilege classification management. |
| Report printing: | 6 formats optional, support custom pattern |
| interface: | TCP/IP network interface |
Working conditions
| Power supply: | AC 110/220V ± 10%, 50/60 Hz, 650W |
| Water consumption: | 8 L/hour (maximum) |
| Dimension: | 745mm X 540mm X 530mm (L x W x H) |
| Weight: | 45.4 Kg |
Four-way floating tabletop

Designed for exibility and e ciency, HM-002A / HM-032A / HM-005A o ers for faster and e ortless operation in every procedure, reducing examination time and improving productivity. A focus on e cient work ow enhances patient care across all applications.

A rotatable X-ray tube makes it possible to achieve examinations from head to toe without repositioning again and again, improving patient comfrot.




Professional workstation of HM-002A / HM-032A / HM-005A delivers superior images of noise reduction, wide dynamic range and enhanced detals.

| Integrated breathing circuit with APL valve, excellent tightness. |
| Replacing drive bellow is NOT required when operating Adult/paediatric anesthesia. |
| Applied with 2 high-precision vaporizer. (Selectatec). |
| 10.1 inch touch screen with no dead space. |
| Real-time detection for loops, Paw, BPM, VT and compliance. |
| Comprehensive monitoring capabilities include ventilation parameters monitoring, preset parameters, alarm indication and breathing waveform monitoring. |
| Head light. |
| Altitude compensation function. |
| ACGO available to connect within T/Bain circuit for open operation. |
| Physical specifications | |
| Dimensions | 70 x 85 x 140cm |
| Weight | 65kg |
| Casters | Front wheels with lock |
| Screen | 10.1-inch LCD / Touch screen |
| Working specifications | |
| Power | AC 110V~240V, 50Hz±2% |
| Pipeline supply | |
| Gas configuration | O₂, N₂O, Air |
| Pipeline input range | 280-600kPa (40~85psi) |
| Battery power | |
| Run-time | ≥ 180 mins |
| Pre-setting functions | |
| Language | ENGLISH |
| Calibration | Automatic |
| Applications | |
| Patient Rang | Adult / Paediatric |
| Ventilator Specifications | |
| Modes of ventilation | |
| VCV | Volume Controlled Ventilation |
| A/C | Assist / Control |
| SIMV | Synchronized Intermittent Mandatory Ventilation |
| MANUAL | Manual |
| PCV | Volume Control Ventilation |
| PSV | Volume Support Ventilation |
| STAND-BY | STAND-BY |
| Ventilator parameter | |
| Working type | Electronic control, pneumatic driven |
| Tidal Volume range | 20-1500ml |
| Pressure range | 5-60 cm H₂O |
| Respiration Rate Range | 1-100bpm (1-40bpm under SIMV) |
| I: E Range | 4:1-1:8 |
| Ptrigger Range | -20-0cm H₂O (based on PEEP) |
| Flow Trigger | 0-15L |
| Minute volume range | >18L/Min |
| SIGH range | 0-5/100 |
| System Standard | |
| Hypoxic guard system | N₂O cut-off valve, O₂ concentration > 21 % |
| Safety valve | <12.5kPa |
| O₂ Flush | 25-75L/min |
| Volume of CO₂ absorber | 2 L |
| Flowmeter | 5 tubes, cascade 0.1-15L/min O₂,
0.1-15L/min N₂O,0.1-15L/min Air |
| Vaporizer | 2 Selectetac, maximum 2 mounts (Isoflurane/Enflurane /Sevoflurane /Halothane) |
| Monitoring | |
| Display graphics | Waveforms of P-T, F-T, V-T; Loops of P-V, V-F, F-P |
| Monitoring | VTi, VTe, MV, Pmax, Pplateau, Ri, CS, Freq, FiO₂, ETCO₂ |
| Alarm Limits | |
| Audio/Visual | No tidal volume, MV, Paw, FiO₂ limitation O₂,
Air failure, AC power failure, Battery low |
| PEEP | |
| Type | Integrated, Electronic control |
| Range | OFF, 3-30cmH₂O |
| • Compact, Light Weight and Thoughtful Design. • User-friendly keyboard with LCD display. • Microprocessor Based Apr Control System. • Great Image Quality. • Stationary Anode X-Ray Tube |
Harold High Frequency Mobile X-Ray is a fine example of an X-ray machine that’s manufactured to meet both national and international standards. The product meets all the essential requirements in terms of ease of use, mobility, maneuverability with high quality images that’s rich in contrast offering excellent diagnostic value. Harold High Frequency Mobile X-Ray is ideally suited for applications in ICUS, OTS, Wards and Sports Centers and can be carried through lifts and narrow corridors.
Benefits of Machine
The machine is ideal for X-Rays of chest, skull, extremities and special investigations including Barium IBP & routine orthopedic examinations.
Salient Features
| 180° rotation | Light, therefore easy to move | Minimum footprint | Easy sliding for convenience |
| Easy to Handle & Compact. | Strong Handlebar with Smart Visualize display. |
| Smaller footprint. | Cassette Cabinet & Sturdy Brake system. |
Advantage of High Frequency Generators
Harold High Frequency X-ray that promises great imaging Across Anatomies
It is also 40% faster!
This translates to:
• Shorter breath hold
• Lesser patient movement
• Great image quality
• Better patient comfort
High Frequency Mobile X-Ray System
Technical Specifications:
|
Model Name |
HM-100 XR | HM-150 XR | HM-150 XR1 |
| Application | Mobile Radiographic | ||
| Generator TYPE | High Frequency Output (maximum 100 kHz) | ||
| Input Voltage | 230V ±10% AC, 50Hz, Single Phase | ||
| Max. Output | 4 kW | 6 kW | 8 kW |
| Rad Kvp Range | 40-100 kV | 40-110 kV | 40-120 kV |
| Rad Ma. Range | 20-100 mA | 20-150 mA | 20-150 mA |
| Rad Mas. Range | 0.1-200 mAs | 0.1-200 mAs | 0.1-250 mAs |
| Rad Time Range | 0.004 to 5 Sec | 0.004 to 5 Sec | 0.004 to 5 Sec |
| Control Panel | LCD Display with Feather Touch Switches and APR Mode. | ||
| X-Ray Tube | Stationary Anode (Monoblock) | ||
| X-Ray Focal Spot | 2.0 mm x 2.0 mm | ||
| Tube Stand | Spring Balance Tube Stand / Motorize Up-Down Movement Tube Stand | ||
| Mobile Unit
Dimensions |
1030 mm L x 635 mm W x 2080 mm H
(40.5″ L x 25″ W x 82″ H) |
||
| Protections | Over Voltage, Over Current, Over Temperature, Earth Fault, Filament Fault, Rotor Fault | ||
]]>